Приказ основних података о дисертацији

Experimental determination of thermal conductivity of binary liquid mixtures using the transient hot wire method

dc.contributor.advisorŽivković, Emila
dc.contributor.otherKijevčanin, Mirjana
dc.contributor.otherMilošević, Nenad
dc.creatorStanimirović, Andrej
dc.date.accessioned2017-06-05T14:05:26Z
dc.date.available2017-06-05T14:05:26Z
dc.date.available2020-07-03T09:25:02Z
dc.date.issued2017-03-21
dc.identifier.urihttps://nardus.mpn.gov.rs/handle/123456789/8259
dc.identifier.urihttp://eteze.bg.ac.rs/application/showtheses?thesesId=5006
dc.identifier.urihttps://fedorabg.bg.ac.rs/fedora/get/o:15672/bdef:Content/download
dc.identifier.urihttp://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=48974351
dc.description.abstractУз несумњиве користи за људску цивилизацију, индустријски развој је донeо и индустријско загађење и могући негативан утицај на климу. Схватање озбиљности проблема прати развој законске регулативе која се односи на испуштање оксида сумпора и угљен диоксида у атмосферу и напредак технолошких поступака примењених на пречишћавање димних гасова. Поред добро познатих и широко примењених поступака развијају се и нови технолошки процеси пречишћавања димних гасова. Регенеративни поступци пречишћавања димног гаса коришћењем органских растварача већ имају релативно дугу историју. Услед одређених ограничења (недовољна селективност процеса, превелики енергетски захтеви) истражују се нови органски растварачи и смеше за примену у регенеративним поступцима пречишћавања димних гасова као ефикаснији апсорбенти SOx и CO2. За ову студију одабрани су органски растварачи већ примењени или са могућом применом у постројењима за пречишћавање димних гасова термоелектрана: моноетаноламин (МЕА), тетраетиленгликол диметилетар (TEGDME), 1-метил-2-пиролидон (NMP), полиетиленгликол 200 (PEG 200), полиетиленгликол 400 (PEG 400) и јонска течност 1-етил-3-метилимидазолијум етил сулфат ([EMIM][EtSO4]). Исто тако, одабране су и следеће бинарне смеше: MEA + TEGDME, MEA + PEG 200, MEA + PEG 400, [EMIM][EtSO4] + PEG 200 и [EMIM][EtSO4] + PEG 400. Моделовање и симулација индустријских процеса и пројектовање постројења за третман димног гаса као улазне податке користе термофизичке особине, између осталог топлотну проводност и вискозност примењених растварача. У оквиру рада на овој дисертацији, за мерење вискозности коришћен је комерцијални инструмент, а за мерење топлотне проводности реализована је експериментална апаратура заснована на нестационарној методи топле жице. Нестационарна метода топле жице се сматра поузданом и прецизном техником за одређивање топлотне проводности течности. Мерна несигурност методе топле жице процењена је на око 1% за најбоље експерименталне апаратуре. Мерење овом методом даје као резултат апсолутну вредност топлотне проводности и не захтева калибрацију или поређење узорка чија се топлотна проводност мери са стандардом. Улазни параметри за прорачун топлотне проводности су промена електричног отпора топле жице, енергија коју генерише електрични пулс који загрева топлу жицу и дужина топле жице. Отпор топле жице се мери стандардном методом четири жице. Електрични пулс пролази кроз редну везу стандардног отпорника и топле жице. Падови напона на стандардном отпорнику и топлој жици мере се компјутерски контролисаним системом за управљање апаратуром и прикупљање података. Програм за прикупљање, иницијалну обраду и чување прикупљених података је такође развијен за ову експерименталну апаратуру. Мерна несигурност апаратуре са топлом жицом процењена је на око ±4%. Тестирање апаратуре обављено је мерењем топлотне проводности добро испитаних течности и мерене вредности одступале су око 3% од литературних података. Резултати експерименталног одређивања топлотне проводности и вискозности наведених чистих супстанци и бинарних смеша су детаљно приказани и упоређени са литературним подацима. Моделовањем топлотне проводности чистих супстанци, применом метода Latini и Sastri, и корелисањем топлотне проводности бинарних смеша, методама Filippov, Jamieson, Baroncini и Rowley, истражена је применљивост модела на испитиване супстанце и смеше.sr
dc.description.abstractAlong with the undoubted benefits for human civilization, industrial development has brought industrial pollution and the possible negative impact on the climate. Understanding of the seriousness of the problem was followed by the development of legislation related to the discharge of sulfur oxides and carbon dioxide into the atmosphere and the progress of technological processes applied to flue gas purification. In addition to the well-known and widely applied methods, new technological processes of flue gas purification have been developed as well. Regenerative flue gas scrubbing processes, using organic solvents, already have a relatively long history. Due to certain limitations of current technologies (insufficient selectivity of the process, large energy requirements) new organic solvents and mixtures are being investigated for use in regenerative flue gas purification as effective SOx and CO2 absorbents. Organic solvents already applied or with possible application in power plant flue gas treatment were selected for this study: monoethanol amine (MEA), tetraethyleneglycol dimethyl ether (TEGDME), 1-methyl-2-pyrrolidone (NMP), polyethylene glycol 200 (PEG 200), polyethylene glycol 400 (PEG 400) and ionic liquid 1-ethyl-3-methylimidazolium ethyl sulphate ([EMIM] [EtSO4]). Also, the following binary mixtures were selected: MEA + TEGDME, MEA + PEG 200, MEA + PEG 400, [EMIM][EtSO4] + PEG 200 and [EMIM][EtSO4] + PEG 400. Modeling and simulation of industrial processes and design of industrial plants for flue gas treatment require thermophysical properties of the applied solvent as input data - thermal conductivity and viscosity, among others. In this study, measurement of viscosity was performed using a commercial instrument, while an experimental measurement apparatus based on the transient hot wire method was set up for measuring thermal conductivity. The transient hot wire method is considered reliable and precise technique for determining thermal conductivity of liquids. The measurement uncertainty of the hot wire technique has been estimated to about 1% for the most developed experimental setups. The measurement yields absolute value of thermal conductivity and does not necessitate calibration or comparison of the sample under test with a standard. Input parameters for the calculation of thermal conductivity are the change in the electrical resistance of the wire, energy generated by the electric pulse that heats the wire and the length of the wire. The hot wire resistance is measured by the standard four-wire method. The current pulse runs through a series connection of the standard resistor and the hot wire. The voltage across the standard resistor and the hot wire are measured by a computer-controlled data acquisition system. The program for collection, initial processing and storage of collected data was also developed for this experimental setup. The measurement uncertainty of the hot wire apparatus has been estimated to about ±4% and measured thermal conductivities of well characterized liquids used to test it deviated about 3% from literature data. The results of experimental determination of thermal conductivity and viscosity of pure substances and binary mixtures listed above are presented and compared with literature data. Applicability of the published models was tested by modeling the thermal conductivity data of pure substances using Latini and Sastri methods and by correlation of thermal conductivity data for binary mixtures by Filippov, Jamieson, Baroncini and Rowley methods.en
dc.formatapplication/pdf
dc.languagesr
dc.publisherУниверзитет у Београду, Технолошко-металуршки факултетsr
dc.rightsopenAccessen
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceУниверзитет у Београдуsr
dc.subjectтоплотна проводностsr
dc.subjectthermal conductivityen
dc.subjectviscosityen
dc.subjectmeasurementen
dc.subjectliquiden
dc.subjectflue gasen
dc.subjectsulfur dioxideen
dc.subjectcarbon dioxideen
dc.subjectmodelingen
dc.subjectвискозностsr
dc.subjectмерењеsr
dc.subjectтечностsr
dc.subjectдимни гасsr
dc.subjectсумпор диоксидsr
dc.subjectугљен диоксидsr
dc.subjectмоделовањеsr
dc.titleЕкспериментално одређивање топлотне проводности бинарних течних смеша применом нестационарне методе топле жицеsr
dc.title.alternativeExperimental determination of thermal conductivity of binary liquid mixtures using the transient hot wire methoden
dc.typedoctoralThesisen
dc.rights.licenseBY-NC-ND
dcterms.abstractЖивковић, Емила; Милошевић, Ненад; Кијевчанин, Мирјана; Станимировић, Aндреј; Eksperimentalno određivanje toplotne provodnosti binarnih tečnih smeša primenom nestacionarne metode tople žice;
dc.identifier.fulltexthttp://nardus.mpn.gov.rs/bitstream/id/18679/IzvestajKomisije9502.pdf
dc.identifier.fulltexthttps://nardus.mpn.gov.rs/bitstream/id/18678/Disertacija.pdf
dc.identifier.fulltexthttps://nardus.mpn.gov.rs/bitstream/id/18679/IzvestajKomisije9502.pdf
dc.identifier.fulltexthttp://nardus.mpn.gov.rs/bitstream/id/18678/Disertacija.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_nardus_8259


Документи за докторску дисертацију

Thumbnail
Thumbnail

Ова дисертација се појављује у следећим колекцијама

Приказ основних података о дисертацији