Приказ основних података о дисертацији
Određivanje protoka tečnosti u složenim uslovima strujanja primenom ravnih elektromagnetnih senzora
Assessment of the Liquid Flow Rate in Complex Flow Conditions with Flat Electromagnetic Sensors
dc.contributor.advisor | Prodanović, Dušan | |
dc.contributor.other | Lečić, Milan | |
dc.contributor.other | Brajović, Ljiljana | |
dc.contributor.other | Mijić, Ana | |
dc.contributor.other | Jaćimović, Nenad | |
dc.creator | Ivetić, Damjan | |
dc.date.accessioned | 2020-11-16T15:12:18Z | |
dc.date.available | 2020-11-16T15:12:18Z | |
dc.date.issued | 2019-10-01 | |
dc.identifier.uri | http://eteze.bg.ac.rs/application/showtheses?thesesId=7749 | |
dc.identifier.uri | https://fedorabg.bg.ac.rs/fedora/get/o:22980/bdef:Content/download | |
dc.identifier.uri | http://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=513822098 | |
dc.identifier.uri | https://nardus.mpn.gov.rs/handle/123456789/17639 | |
dc.description.abstract | Pouzdano poznavanje protoka predstavlja preduslov za adekvatno dimenzionisanje hidrotehničkih sistema. Pored toga, upravljanje postojećim sistemima se često vrši na osnovu izmerenih podataka o protoku. Međutim, u sistemima gde se javlja tečenje sa slobodnom površinom, posebno u kanalizacionim sistemima, određivanje protoka je komplikovan i zahtevan zadatak... | sr |
dc.description.abstract | Reliable flow data are a precondition for adequate designing of hydraulic systems. Additionally, hydraulic system control is frequently based on the measured flow rate data. However, in the systems with free surface flow, and especially sewer systems, flow rate assessment is a complex and challenging task... | en |
dc.format | application/pdf | |
dc.language | sr | |
dc.publisher | Универзитет у Београду, Грађевински факултет | sr |
dc.relation | info:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/37010/RS// | |
dc.rights | openAccess | en |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Универзитет у Београду | sr |
dc.subject | Merenje protoka | sr |
dc.subject | Flow measurement | en |
dc.subject | velocity measurement | en |
dc.subject | V – A method | en |
dc.subject | electromagnetic sensors | en |
dc.subject | measurement uncertainty | en |
dc.subject | local calibration | en |
dc.subject | merenje brzine | sr |
dc.subject | V – A pristup | sr |
dc.subject | složeni uslovi strujanja | sr |
dc.subject | elektromagnetni senzori | sr |
dc.subject | merna neodređenost | sr |
dc.subject | lokalna kalibracija | sr |
dc.title | Određivanje protoka tečnosti u složenim uslovima strujanja primenom ravnih elektromagnetnih senzora | sr |
dc.title.alternative | Assessment of the Liquid Flow Rate in Complex Flow Conditions with Flat Electromagnetic Sensors | en |
dc.type | doctoralThesis | en |
dc.rights.license | BY-NC-ND | |
dcterms.abstract | Продановић, Душан; Мијић, Aна; Брајовић, Љиљана; Јаћимовић, Ненад; Лечић, Милан; Иветић, Дамјан; Одређивање протока течности у сложеним условима струјања применом равних електромагнетних сензора; Одређивање протока течности у сложеним условима струјања применом равних електромагнетних сензора; | |
dc.identifier.fulltext | https://nardus.mpn.gov.rs/bitstream/id/66917/IzvestajKomisije23466.pdf | |
dc.identifier.fulltext | https://nardus.mpn.gov.rs/bitstream/id/66916/Disertacija.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_nardus_17639 |