Приказ основних података о дисертацији
Процесне перформансе колоне са испуном при вакуумској дегазацији воде
Process performances of packed column for water degassing under vacuum
dc.contributor.advisor | Genić, Srbislav | |
dc.contributor.other | Stamenić, Mirjana | |
dc.contributor.other | Aranđelović, Ivan | |
dc.contributor.other | Karličić, Nikola | |
dc.contributor.other | Jovanović, Jovan D. | |
dc.creator | Ivošević, Miloš | |
dc.date.accessioned | 2021-03-23T10:30:45Z | |
dc.date.available | 2021-03-23T10:30:45Z | |
dc.date.issued | 2020-07-17 | |
dc.identifier.uri | http://eteze.bg.ac.rs/application/showtheses?thesesId=8005 | |
dc.identifier.uri | https://fedorabg.bg.ac.rs/fedora/get/o:23392/bdef:Content/download | |
dc.identifier.uri | http://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=31439625 | |
dc.identifier.uri | https://nardus.mpn.gov.rs/handle/123456789/18157 | |
dc.description.abstract | Предмет ове докторске дисертације је истраживање процесних параметара вакуумског дегазатора напојне воде са насутом испуном за системе даљинског грејања и формирање оригиналне прорачунске процедуре. У дисертацији је дат преглед прорачунских процедура, доступних у отвореној литератури, које су данас најзаступљеније у практичном инжењерском раду. Показано је да анализиране методологије доводе до поддимензионисања апарата односно до апарата са недовољном висином испуне. На основу резултата експерименталних испитивања на индустријском вакуумском дегазатору, формирана је оригинална корелација за прорачун коефицијента прелаза супстанције у течности предметног типа апарата. Ова процедура, односно корелација, може да се користи за прорачун и димензионисање нових апарата, као и за анализу рада постојећих апарата овог типа. | sr |
dc.description.abstract | The subject of this doctoral dissertation is the research of process parameters of a vacuum degasser with random packing used for water degassing in district heating systems and formation of the original design procedure. The dissertation gives an overview of the calculation procedures available in the open literature, which are the most represented in practical engineering work. It has been shown that the methodologies analyzed could lead to an undersizing of the apparatus i.e. to a insufficient height of the packed bed. Based on the experimental testing of industrial vacuum degasser, an original correlation for calculation of the mass transfer coefficient in a liquid phase of this type of apparatus has been formed. This procedure i.e. correlation, can be used for design and sizing of new equipment, as well as for performance analysis of existing equipment of this type. | en |
dc.format | application/pdf | |
dc.language | sr | |
dc.publisher | Универзитет у Београду, Машински факултет | sr |
dc.rights | openAccess | en |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Универзитет у Београду | sr |
dc.subject | Колоне са насутом испуном | sr |
dc.subject | packed columns | en |
dc.subject | mass transfer coefficient | en |
dc.subject | vacuum degassing | en |
dc.subject | коефицијент прелаза супстанције | sr |
dc.subject | вакуумска дегазација | sr |
dc.title | Процесне перформансе колоне са испуном при вакуумској дегазацији воде | sr |
dc.title.alternative | Process performances of packed column for water degassing under vacuum | en |
dc.type | PhD thesis | |
dc.rights.license | BY-NC-ND | |
dcterms.abstract | Генић, Србислав; Стаменић, Мирјана; Aранђеловић, Иван; Јовановић, Јован Д.; Карличић, Никола; Ивошевић, Милош; Procesne performanse kolone sa ispunom pri vakuumskoj degazaciji vode; | |
dc.identifier.fulltext | https://nardus.mpn.gov.rs/bitstream/id/70388/Disertacija.pdf | |
dc.identifier.fulltext | https://nardus.mpn.gov.rs/bitstream/id/70389/IzvestajKomisije28517.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_nardus_18157 |