Show simple item record

Real power grid harmonic measurement method using 2-bit A/D converters

dc.contributor.advisorMitrović, Zoran
dc.contributor.otherSovilj, Platon
dc.contributor.otherKovačević, Dragan
dc.contributor.otherSpasić-Jokić, Vesna
dc.contributor.otherPejić, Dragan
dc.contributor.otherMitrović, Zoran
dc.creatorBeljić, Željko
dc.date.accessioned2017-01-23T10:50:33Z
dc.date.available2017-01-23T10:50:33Z
dc.date.issued2016-12-29
dc.identifier.urihttp://www.cris.uns.ac.rs/DownloadFileServlet/Disertacija147748165112717.pdf?controlNumber=(BISIS)102312&fileName=147748165112717.pdf&id=6990&source=NaRDuS&language=srsr
dc.identifier.urihttp://www.cris.uns.ac.rs/record.jsf?recordId=102312&source=NaRDuS&language=srsr
dc.identifier.urihttp://www.cris.uns.ac.rs/DownloadFileServlet/IzvestajKomisije147748166185410.pdf?controlNumber=(BISIS)102312&fileName=147748166185410.pdf&id=6991&source=NaRDuS&language=srsr
dc.identifier.uri/DownloadFileServlet/IzvestajKomisije147748166185410.pdf?controlNumber=(BISIS)102312&fileName=147748166185410.pdf&id=6991
dc.identifier.urihttp://nardus.mpn.gov.rs/123456789/7430
dc.description.abstractU disertaciji je prikazano teorijsko i praktično istraživanje koje se odnosi na utvrđivanje potrebnih i dovoljnih uslova za merenje harmonika u realnoj elektrodistributivnoj mreži. Cilj istraživanja doktorske disertacije je formulisanje merne metode i na metodi baziranom hardveru - po mogućnosti minimalne rezolucije primenjenih A/D konvertora - praktično dvobitnih za merenje harmonika u realnoj elektrodistributivnoj mreži. Jednostavan hardver omogućuje jednostavna paralelna merenja, kao i mali broj izvora sistematske greške merenja, što je vrlo primenljivo u merenjima u realnoj distributivnoj mreži.Simulacionom analizom, a potom i eksperimentom potvrđena je hipoteza istraživanja.sr
dc.description.abstractThe dissertation shows the theoretical and practical research related to the determination of necessary and sufficient conditions for the measurement of harmonics in a real power grid. The aim of the PhD research is to formulate method and hardware based on the measurement method - preferably with minimal resolution of applied A/D converter - practically 2-bit, for harmonics measurement in a real power grid. Simple hardware allows simple parallel measurements, as well as a small number of systematic measurement error, which is applicable for measurement in the real power grid. Simulation analysis, followed by the experiment, confirmed the hypothesis of this research.en
dc.languagesr (latin script)
dc.publisherУниверзитет у Новом Саду, Факултет техничких наукаsr
dc.rightsAttribution-NonCommercial-NoDerivs
dc.sourceУниверзитет у Новом Садуsr
dc.subjectMerenje harmonika, dvobitni A/D konvertor, varijacija frekvencije, kvalitet električne energije, Stohastička merna metodasr
dc.subjectHarmonics measurement, two-bit A/D converter, frequency variation, power quality, Stochastic measurement methoden
dc.titleMetoda merenja harmonika u realnoj distributivnoj mreži primenom A/D konvertora dvobitne rezolucijesr
dc.title.alternativeReal power grid harmonic measurement method using 2-bit A/D convertersen
dc.typeDoktorska disertacijasr
dcterms.abstractМитровић Зоран; Пејић Драган; Совиљ Платон; Ковачевић Драган; Спасић-Јокић Весна; Митровић Зоран; Бељић Жељко; Метода мерења хармоника у реалној дистрибутивној мрежи применом A/Д конвертора двобитне резолуције; Метода мерења хармоника у реалној дистрибутивној мрежи применом A/Д конвертора двобитне резолуције;


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record