Приказ основних података о дисертацији

Influence of the scintillation crystal option on the detector response of pet devices

dc.contributor.advisorStanković, Koviljka
dc.contributor.otherMarinković, Predrag
dc.contributor.otherObradović, Vladimir
dc.contributor.otherCiraj-Bjelac, Olivera
dc.contributor.otherPopović, Dejan V.
dc.creatorAntić, Vojislav M.
dc.date.accessioned2016-07-23T16:09:46Z
dc.date.available2016-07-23T16:09:46Z
dc.date.available2020-07-03T08:34:37Z
dc.date.issued2015-03-20
dc.identifier.urihttps://nardus.mpn.gov.rs/handle/123456789/5966
dc.identifier.urihttp://eteze.bg.ac.rs/application/showtheses?thesesId=3328
dc.identifier.urihttps://fedorabg.bg.ac.rs/fedora/get/o:11790/bdef:Content/download
dc.identifier.urihttp://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=47587343
dc.description.abstractPozitronska emisiona tomografija (PET) je tehnologija koja pruža jedinstvene i izuzetne mogućnosti u funkcionalnoj dijagnostici u smislu da se pomoću do sada najefikasnije i najpouzdanije metode dolazi do informacije o biohemijskoj aktivnosti i ćelijskom metabolizmu u telu, određivanjem tačne lokalizacije i vršenjem semikvantitativne procene distribucije radioaktivne supstance. U ovom radu porede se karakteristike nedavno uvedenih kristala na bazi lutecijuma (LYSO) sa karakteristikama konvencionalnih bizmut-orto-germanat (BGO) scintilatora. Ispitane su sledeće scintilacione karakteristike PET kristala: osetljivost, energetska rezolucija, svetlosni prinos, svojstvena energetska rezolucija, atenuacija γ zraka kroz scintilacione kristale, radijaciona dužina, Molijerov radijus, vreme gašenja svetlosnog impulsa u scintilacionom kristalu, vreme preleta (TOF eng. „Time of Flight“) i refrakcioni indeks. Razmatran je uticaj fizičko-hemijskih i električnih osobina scintilatora na odziv detektora, uparenost svih parametara PET scintilatora, dimenzionisanje detektorskih kristala, „organizacija“ u PET blok detektore i povezivanje sa PET fotomultiplikatorima, sve u cilju dobijanja što kvalitetnije PET medicinske slike.sr
dc.description.abstractPositron emission tomography (PET) is a technology that provides unique and exquisite possibilities in functional diagnostics, in the sense that it is the most efficient and most reliable method for obtaining information about biochemical activity and cellular metabolism in the body, by determining exact localization and performing semi-quantitative assessment of the distribution of a radioactive tracer. This work compares the characteristics of recently introduced lutetium based crystals (LYSO) to those of conventionally used bismuth-ortho-germanate scintillators (BGO) The following characteristis of PET crystals have been investigated: energy resolution, scintillation decay time, sensitivity, light yield, intrinsic energy resolution, atenuation of gama radiation in scintilation crystal, radiation length, time of flight, Moliere radius, refraction index. The influence of scintilators’ physical, chemical and electric properties on the detector response are considered and analyzed, as well as the PET scintilation parameters pairing, dimensioning of detector crystals, their organizing in PET block detectors and linking to PET photomultipliers, all in order to obtain a higher quality of PET medical image.en
dc.formatapplication/pdf
dc.languagesr
dc.publisherУниверзитет у Београду, Електротехнички факултетsr
dc.rightsopenAccessen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceУниверзитет у Београдуsr
dc.subjectpozitronska emisiona tomografijasr
dc.subjectpositron emission tomographyen
dc.subjectscintillation crystalen
dc.subjectdetector responseen
dc.subjectscintilacioni kristalsr
dc.subjectodziv detektorasr
dc.titleUticaj izbora scintilacionog kristala na odziv detektora kod pet uređajasr
dc.titleInfluence of the scintillation crystal option on the detector response of pet devicesen
dc.typedoctoralThesisen
dc.rights.licenseBY
dcterms.abstractСтанковић, Ковиљка; Маринковић, Предраг; Обрадовић, Владимир; Цирај-Бјелац, Оливера; Поповић, Дејан В.; Aнтић, Војислав М.; Утицај избора сцинтилационог кристала на одзив детектора код пет уређаја; Утицај избора сцинтилационог кристала на одзив детектора код пет уређаја;
dc.identifier.fulltexthttps://nardus.mpn.gov.rs/bitstream/id/5351/Disertacija3926.pdf
dc.identifier.fulltexthttps://nardus.mpn.gov.rs/bitstream/id/5352/Antic_Vojislav_M.pdf
dc.identifier.fulltexthttp://nardus.mpn.gov.rs/bitstream/id/5351/Disertacija3926.pdf
dc.identifier.fulltexthttp://nardus.mpn.gov.rs/bitstream/id/5352/Antic_Vojislav_M.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_nardus_5966


Документи за докторску дисертацију

Thumbnail
Thumbnail

Ова дисертација се појављује у следећим колекцијама

Приказ основних података о дисертацији