Приказ основних података о дисертацији

Apsolutno određivanje aktivnosti gama emitera pomoću jednog detektora

dc.contributor.advisorBikit, Ištvan
dc.contributor.otherMrđa, Dušan
dc.contributor.otherBikit, Ištvan
dc.contributor.otherSatarić, Miljko
dc.contributor.otherKozmidis-Petrović, Ana
dc.creatorНемеш, Томас
dc.date.accessioned2015-12-29T11:16:59Z
dc.date.available2015-12-29T11:16:59Z
dc.date.available2020-07-03T13:42:53Z
dc.date.issued2015-07-10
dc.identifier.urihttps://nardus.mpn.gov.rs/handle/123456789/1696
dc.identifier.urihttp://www.cris.uns.ac.rs/DownloadFileServlet/Disertacija144230232392126.pdf?controlNumber=(BISIS)94841&fileName=144230232392126.pdf&id=4316&source=NaRDuS&language=srsr
dc.identifier.urihttp://www.cris.uns.ac.rs/record.jsf?recordId=94841&source=NaRDuS&language=srsr
dc.identifier.urihttp://www.cris.uns.ac.rs/DownloadFileServlet/IzvestajKomisije143030580225492.pdf?controlNumber=(BISIS)94841&fileName=143030580225492.pdf&id=3629&source=NaRDuS&language=srsr
dc.description.abstractИспитана је тачност методе мерења апсолутне активности гама емитера помоћу једног гама спектрометра на већим брзинама бројања. У оквиру истраживања нађен је једноставан поступак за корекцију спектралних података на случајне коинциденције.    Принцип коинцидентне технике и корекције сумарног врха и врхова пуне енергије помоћу врхова у спектру насталим само услед случајних коинциденција примењен је на радиоизотопе са једноставном и веома сложеном шемом. Изведене су једноставне формуле за мерења активности са и без корекције на ефективне угаоне корелације у којима фигуришу подаци само из једног гама спектра чиме је постигнута знатна једноставност у техници мерења.    Резултати овог истраживања показали су да се активност двофотонских гама емитера може измерити помоћу HPGe детектора и дигиталне спектроскопске јединице са тачношћу испод 1% на разним брзинама бројања само помоћу једног спектра. Резултати за изотопе са сложеном шемом добијени једноставном техником указују да се техника може применити на рутинска мерења где грешка не превазилази 10%sr
dc.description.abstractIspitana je tačnost metode merenja apsolutne aktivnosti gama emitera pomoću jednog gama spektrometra na većim brzinama brojanja. U okviru istraživanja nađen je jednostavan postupak za korekciju spektralnih podataka na slučajne koincidencije.    Princip koincidentne tehnike i korekcije sumarnog vrha i vrhova pune energije pomoću vrhova u spektru nastalim samo usled slučajnih koincidencija primenjen je na radioizotope sa jednostavnom i veoma složenom šemom. Izvedene su jednostavne formule za merenja aktivnosti sa i bez korekcije na efektivne ugaone korelacije u kojima figurišu podaci samo iz jednog gama spektra čime je postignuta znatna jednostavnost u tehnici merenja.    Rezultati ovog istraživanja pokazali su da se aktivnost dvofotonskih gama emitera može izmeriti pomoću HPGe detektora i digitalne spektroskopske jedinice sa tačnošću ispod 1% na raznim brzinama brojanja samo pomoću jednog spektra. Rezultati za izotope sa složenom šemom dobijeni jednostavnom tehnikom ukazuju da se tehnika može primeniti na rutinska merenja gde greška ne prevazilazi 10%sr
dc.description.abstractIt has been investigated the accuracy of absolute activity measurement of gamma emitters with a single gamma spectrometer at higher count rates. In this research it has been found relatively simple procedure for random summing correction of spectral data. Principle of coincidence technique and random summing correction of sum peaks and full energy peaks using pile up peaks is applied to measure absolute activity of simple and complicated decay scheme radioisotopes. Simple equations were deduced for absolute activity measurements with and without correction for effective angular correlations. Variables in these equations are spectral data only. Great simplicity is achieved in coincidence technique of absolute activity measurement. It was shown that absolute activity of radioisotopes emitting simultaneously two gamma photons can be measured with accuracy below 1% at high count rates using HPGe detector and DSP spectroscopy unit. Measurements of complicated decay scheme radioisotopes shown that simple technique is able to bring satisfactory results with accuracies below 10%en
dc.languagesr (cyrillic script)
dc.publisherУниверзитет у Новом Саду, Природно-математички факултетsr
dc.rightsopenAccessen
dc.rights.urihttps://creativecommons.org/licenses/by-nd/4.0/
dc.sourceУниверзитет у Новом Садуsr
dc.subjectАпсолутна активностsr
dc.subjectApsolutna aktivnostsr
dc.subjectAbsolute activityen
dc.subjectгама спектрометарsr
dc.subjectкоинцидентно мерењеsr
dc.subjectправе и случајне коинциденцијеsr
dc.subjectgama spektrometarsr
dc.subjectkoincidentno merenjesr
dc.subjectprave i slučajne koincidencijesr
dc.subjectgamma spectrometeren
dc.subjectcoincidence measurementen
dc.subjecttrue and random coincidencesen
dc.titleАпсолутно одређивање активности гама емитера помоћу једног детектораsr
dc.titleApsolutno određivanje aktivnosti gama emitera pomoću jednog detektorasr
dc.titleAbsolute activity measurement of gamma emitters with a single detectoren
dc.typedoctoralThesisen
dc.rights.licenseBY-ND
dcterms.abstractБикит Иштван; Бикит Иштван; Мрђа Душан; Сатарић Миљко; Козмидис-Петровић Aна; Nemeš Tomas; Aпсолутно одређивање активности гама емитера помоћу једног детектора; Aпсолутно одређивање активности гама емитера помоћу једног детектора; Apsolutno određivanje aktivnosti gama emitera pomoću jednog detektora;
dc.identifier.fulltexthttps://nardus.mpn.gov.rs/bitstream/id/38069/IzvestajKomisije.pdf
dc.identifier.fulltexthttp://nardus.mpn.gov.rs/bitstream/id/38069/IzvestajKomisije.pdf
dc.identifier.fulltexthttps://nardus.mpn.gov.rs/bitstream/id/38068/Disertacija.pdf
dc.identifier.fulltexthttp://nardus.mpn.gov.rs/bitstream/id/38068/Disertacija.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_nardus_1696


Документи за докторску дисертацију

Thumbnail
Thumbnail

Ова дисертација се појављује у следећим колекцијама

Приказ основних података о дисертацији